SPECIAL PROGRAMMING SECTION:
CREATING THE PROGRAM CODE
The Program Code is the pass-
word used to change program-
ming. The program code is stored in address “00”.
1. Remove the battery access cover to gain access to the “PRGM” button.
2. Press “PRGM” button.
3. Yellow light on keypad will flash rapidly indicating program mode.
While in the program mode, yellow light will continue to flash until exit the pro-
gram mode or after a 30-second timeout period where there is no keystroke.
4. Press “00” for program code address.
5. Enter new 5 - 7 digit Program Code within 5 seconds.
6. When new Program Code is entered, wait for the red light to flash twice
confirming valid entry. A long red flash indicates an error.
SET USER CODES
User codes are stored in addresses “01” through “55”. SABL must be in Pro-
gram Mode to add or delete User Codes.
1. Enter Program Code.
2. Press “E” button.
3. Yellow keypad light will flash rapidly indicating program mode.
4. Press two digit prefix for new User Code address.
5. Enter new 1- 7 digit User Code within 5 seconds.
6. Wait for red light to flash twice to confirm valid entry.
7. Press “E” to exit program mode.
To delete individual user codes, enter “79” then any User Code.
To delete all users codes, enter “88” (not program or hard code).
PASSAGE CODES OR LOCKOUT CODES
The passage codes are stored in addresses “56” and “57”. Lockout codes are
stored in addresses “58” and “59”.
1. Enter Program Code.
2. Press the “E” button.
3. Yellow keypad light will flash rapidly indicating program mode.
4. Enter “56” for passage code or “58” for lockout code within 5 seconds.
5. When desired code is entered, wait for red light to flash twice confirming
valid entry.
6. Press “E” to exit program mode.
To reverse passage or lockout code: Repeat above steps entering “57” to
exit passage or “59” to exit lockout code within 5 sec. Red light flashES twice
confirming valid entry. Press “E” to exit program mode.
RESET TO FACTORY DEFAULT, MASTER CODE UNKNOWN:
Press “HARD” button on CPU board for 1 second
Flashing yellow LED. Press “E” key until flashing stops
Confirm two (2) red flashes. Press the “PRGM” buttonon CPU board for
one second. Confirm flashing yellow LED
Enter 0-0 followed by “E” key. Confirm two (2) red flashes.
Enter 8-8 followed by “E” key. Confirm two (2) red flashes.
Enter 8-9 followed by “E” key. Confirm two (2) red flashes.
Press the “E” key to end yellow flashing LED.
Lock is back to default values
SECURITRON SABL
Categories Securitron SABL
ANSI/BHMA A156.2
Cylindrical Lock
Grade 1
UL/ULC fire rating 3-hour ‘A’ Label doors
Clutched Lever Clutched Exterior Lever
Available as Cylindrical Lock
Lever Handing Non-handed
(field reversible) Yes
Key Override Yes
Optional No
Keypad Layout 11 buttons, 1-0 and “E”
Button Construction EPDM rubber keys
Code Hierarchy Program Code, User
Codes
Master Code Program Code
Number Of Digits 5-7, only for
programming
Factory Default
Master
Created Program
Code is stored at
address “00”. Must
press “PRGM” button
adjacent to batteries
Sub-master Codes n/a
User Codes no. up to 55, 2-7 digits
Single use code n/a
Successful Code
Entry (lock/
unlocked)
Flash once per second
red LED. Can be
reversed to green LED
Levels of access Code Required,
Passage, Lock-out
Lock-out Override User locations 58 and
59. Code required to
enter and exit Lock-out
Anti-Tamper After 16 wrong digits
entered, keypad will
lock for 15 seconds,
beeper sounds
continuously
Weatherized Fully sealed exterior
electronics
Battery Life Over 100,000 cycles
Low Batteries
Warning
Two short beeps and
flash of LEDs at first
keystroke. Second, two
short beeps and LED
flash at each keystroke
Batteries 6 AA Alkaline
Battery Location Inside battery cover,
3/32” hex (Allen)
wrench
Replacement Non-volatile EEPROM
memory, no time
limitation
56 — LOCKSMITH LEDGER [11/10] www.locksmithledger.com