SPECIAL PROGRAMMING SECTION:
T
he Cobra lock does not have Master
or Sub-Master Codes. Instead, appli-
cation codes include:
Normal Codes, Toggle Codes that either
unlock (passage mode) or relock (Code
required) and Freeze/Lockout Codes that
unlock or relock locks, and prevents other
codes from operating the locks.
One Use Codes unlock lock only once
for the unlocked time. Supervised Codes
requires two different codes to unlock lock
for the unlock time. Pass Thru Codes will
unlock the door for the unlock time even in
lockout mode.
Add Normal User Code: Enter Program Code
*, 3 *, Enter New Code, * *. To add more,
enter new code * *. To end, *.
Add One-Time User Code: Enter Program Code
*, 33 *, 113 *, enter new code, **. To add
more, enter new code **. To end, *.
Add Toggle Code: Enter Program Code *, 33
*, 191, *. Enter new code, **. To add more,
enter new code **. To end, *.
Add Freeze/Lockout Code: Enter Program Code
*, 33 *, 115 *, New Code, **. To add more,
enter New code, **. To end, *.
Add Supervised Code: Enter Program Code
*, 33 *, 117, * New Code, **. To add more,
enter New Code, **. To end, *.
Add Pass Through Code: Enter Program Code
*, 33 *, 119*. Enter New Code **. To add
more, enter New Code **. To end, *.
Change Programming Code: Enter Program
Code *, 7 *, New Program Code, *, Enter
New Program Code again, *.
Delete Codes: Enter
Program Code *, 5 *,
Code to be deleted * *.
To delete more, enter
Code to be deleted **.
To end, *
Categories MPC Cobra Lock
ANSI/BHMA A156.2 Cylindrical Lock Grade Grade 1
UL/ULC fire rating UL - cUL Fire Label forall functions up to
3 hours
Clutched Lever n/a
Available as Cylindrical
Lever Handing Non-handed
Field reversible? Yes
Key Override Yes
Optional No
Notes: Standard cylinder or 7-pin IC
Keypad Layout 6 buttons, 2 rows, 1-2, 3-4, 5-6, 7-8, 9-0, *
Notes: Each keypad button represents two numbers. For example, code 246 is
identical to code 135)
Button Construction Metal
Code Hierarchy Programming Code, Normal Code, Toggle
Code, Freeze/Lockout Code, One Use,
Supervised, Pass Thru
Master Code Programming Code
Number Of Digits 5-8 digits
Factory Default 97531
Notes: Only programs codes
Cannot unlock door
Sub-master Codes no. n/a
User Codes. Up to 99
number of digits 3-8
Notes: Six types of User Codes. Each has special
applications
Single use (Service Code) up to 99
Successful Entry Green LED flashes during unlock time,
rotate handle to retract latch
User code groups n/a
Levels of access One
Lock-out/down ovverridden by Freeze/Lockout Code
Programming Capabilities Program Code only
Codes on hold Freeze/Lockout Code
Anti-Tamper n/a
Weatherized model n/a
Battery Life Approximately 80,000 cycles
Low Batteries Warning First code entered, red LED flashes 12
times before the command executed.
After about 500 cycles, lock goes into “Low Battery Lockout” mode. Freeze/Lockout
Code required to gain access
Batteries Four AA
Battery Location Inside escutcheon cover, Four
hi-Security Snake Eyes Screws
Battery Replacement Warning Must replace batteries within 10 min
SCHLAGE COBRA
TO RESET FACTORY DEFAULT:
Clearing memory will delete all programmed codes and restore factory de-
fault codes. If the memory needs to be erased, follow these steps.
1. Remove inside escutcheon and remove one battery
2. Press any key
3. Hold down * key and reinstall battery. Continue holding the * key
down until red LED flashes a few times and then stays on.
4. Release * key
5. Install inside escutcheon.
To return to factory default relock time delay, do steps 1-4 twice in a row.
www.locksmithledger.com [11/10] LOCKSMITH LEDGER — 55