SPECIAL PROGRAMMING SECTION:
T
he Factory Master Code
(12345) may not be used for
programming; a new Master
Code must first be programmed
into the lock. All other codes must
have the same number of digits
(3-5) as the new Master Code.
Programming New Master Code: Enter
existing Master Code, then Program
Address before unit relocks. Enter new
Master Code, then press [AL]. Verify as
follows.
Press 12354 (factory master
code), hear beep, [AL] [1] [AL], new
master code number, [AL] again. To
verify, enter new master code again
and you should hear 6 beeps.
Management Code: Enter Master Code,
then [AL] [2] [AL] (before unit relocks.
Enter Management Code. You should
hear 6 beeps.
User 1 Code: Enter Master or Manage-
ment Code, then [AL] [1] [1] [AL], then
enter User 1 Code. Again, 6 beeps
means programming was successful.
User 2 Code: [AL] [1] [2] [AL], User 2
Code
User 3 Code: [AL] [1] [3] [AL], User 3
Code
User 4 Code: [AL] [1] [4] [AL], User 4
Code
User 5 Code: [AL] [1] [5] [AL], User 5
Code
User 6 Code: [AL] [2] [1] [AL], User 6
Code
User 7 Code: [AL] [2] [2] [AL], User 7
Code
User 8 Code: [AL] [2] [3] [AL], User 8
Code
User 9 Code: [AL] [2] [4] [AL], User 9
Code
User 10 Code: [AL] [2] [5] [AL], User 10
Code
User 11 Code: [AL] [3] [1] [AL], User 11
Code
User 12 Code: [AL] [3] [2] [AL], User 12
Code
User 13 Code: [AL] [3] [3] [AL], User 13
Code
User 14 Code: [AL] [3] [4] [AL], User 14
Code
User 15 Code: [AL] [3] [5] [AL], User 15
Code
Service Code: [AL] [3] [AL], Service
Code
User Code provides entry only.
To disable any user, enter Master or
Manager Code, respective program
address, but no User Code. Allow
unit to relock.
FUNCTIONS
To program the following func-
tions, first enter Master or Manage-
ment Code, then respective pro-
gram address before unit relocks.
Disable Bank 1 Users: [AL] [5] [1] [AL]
Disable Bank 2 Users: [AL] [5] [2] [AL]
Disable Bank 3 Users: [AL] [5] [3] [AL]
Disable Banks 1-3: [AL] [5] [5] [AL]
Re-enable Bank 1: [AL] [4] [1] [AL]
Re-enable Bank 2: [AL] [4] [2] [AL]
Re-enable Bank 3: [AL] [4] [3] [AL]
Re-enable Banks 1-3: [AL] [4] [4] [AL]
Enable Passage: [AL] [4] [AL], program-
mable by Master only
Disable Passage: [AL] [5] [AL], program-
mable by Master only
Battery Replacement: Must be replaced
within two minutes to avoid losing
memory. Do not press any buttons
when replacing batteries
RESET PROGRAMMING TO FACTORY
DEFAULT:
Remove batteries and press any
button
ALARM LOCK DL2700
www.locksmithledger.com [11/10] LOCKSMITH LEDGER — 47www.locksmithledger.com [11/10] LOCKSMITH LEDGER — 47
Categories Alarm Lock DL
2700
ANSI/BHMA A156.2
Cylindrical Lock Grade
Grade 1
UL/ULC fire rating 3 Hours, “A”
labeled doors
Cylindrical or mortise Cylindrical
Clutched Lever Yes
Lever Handing non-handed
(field reversible) Yes
Key Override Yes
Optional No
Keypad Layout Telephone Style,
12 button
Button Construction Metal
Code Hierarchy Master,
Management,
User Codes
Master Code One
Number Of Digits 3 to 5
Factory Default Master 1-2-3-4-5
Note: Changing Master erases all codes
Sub-Master Codes no. 1
Number Of Digits Same as Master
User Codes Up to 15
number of digits Same as Master
Single use code
(Service Code)
Up to 2
Successful entry Beeps sounds,
Green LED
flashes
User code groups 3, 5 codes per
group
Levels of access Code Required,
Passage, User,
Group or All
Lock-out
Lock-out Override Master or
Management
Programming Capabilities:
Master Code All
Sub-Masters Limited
Anti-Tamper 3 invalid code
entries shuts
down lock for
approximately 20
seconds
2 beeps when
reactivated
Battery Life Up to 175,000
cycles
Weatherized model Optional
Low Batteries Warning 5 second dual
tone when any
key is pressed
Batteries 5AA Alkaline
Battery Location Interior Housing,
Screw at bottom